Description                                    
                                                                                                    
                                        Specifications                                    
                                                                                                    
                                        Download                                    
                                                            Description
                                    - The amplifier "YENISEY D15.0" is designed to amplify the signal of the nominal level 0.775V (0dB) coming from the source of the sound program to the level of 240V (50dB) at the nominal load
- The amplifier is made in the form of a 19" rack, which houses a set of blocks providing a power of 15000 W
 
- Amplifier output transformer balanced, protected by a fusible link
 
- The amplifier is powered from a three-phase AC network with a voltage of 3x380V, 50Hz, with the obligatory connection of the neutral and ground wires.
 
- The amplifier has a protection system:
 Thermal protection circuit implemented in the power amplifier unit
 Circuit for monitoring the health of fuses in the audio signal path
 Overload protection circuit in each PSU (power supply)
 It is provided to turn off the amplifier when any of the phases is lost
 
 
- Wired broadcasting networks
 
- As part of warning systems for civil defense and emergencies
 
- As part of systems used to conduct vibration tests
 
Specifications
                                    Parameter name
                                                                                                            
                                                             Rated value                                                        
                                                                                                            
                                                             Limit                                                        
                                                                                                    Rated output voltage
                                                                                                            
                                                             240 V                                                        
                                                                                                            
                                                             ± 12 V                                                        
                                                                                                    Rated input voltage corresponding to the rated output
                                                                                                            
                                                             0,775 V                                                        
                                                                                                            
                                                             ± 0,04 V                                                        
                                                                                                    Rated output power when operating 
on an active load 92.16 Ohm
                                                                                                            on an active load 92.16 Ohm
                                                             15000 W                                                        
                                                                                                            
                                                             ±1500 W                                                        
                                                                                                    Bandwidth transmitted frequencies
                                                                                                            
                                                             50-10000 Hz                                                        
                                                                                                            
                                                             -                                                        
                                                                                                    Permissible deviations of the amplitude-frequency characteristic (AFC), relative to the frequency
of 1000 Hz, max, at frequencies:
- 25 Hz
- from 25 Hz to 75 Hz inclusive
- over 75 Hz up to and including 100 Hz
- over 100 Hz up to and including 6600 Hz
- over 6600 Hz up to and including 10000 Hz
- 20000 Hz
                                                                                                            of 1000 Hz, max, at frequencies:
- 25 Hz
- from 25 Hz to 75 Hz inclusive
- over 75 Hz up to and including 100 Hz
- over 100 Hz up to and including 6600 Hz
- over 6600 Hz up to and including 10000 Hz
- 20000 Hz
                                                             -10,5 dB
-2,5 dB
-1 dB
±0,6 dB
1/-1,5 dB
-9 dB
                                                                                                            -2,5 dB
-1 dB
±0,6 dB
1/-1,5 dB
-9 dB
                                                             ±4,5 dB
±1,5 dB
±1,0 dB
-
-
±3,0 dB
                                                                                                    ±1,5 dB
±1,0 dB
-
-
±3,0 dB
Harmonic coefficient, max:
- at input voltage levels from minus 20 dB to the nominal value, at frequencies:
- up to 100 Hz
- from 100 Hz to 200 Hz inclusive
- over 200 Hz
- when the input signal level is 12 dB above the nominal value at a frequency of 1000 Hz
                                                                                                            - at input voltage levels from minus 20 dB to the nominal value, at frequencies:
- up to 100 Hz
- from 100 Hz to 200 Hz inclusive
- over 200 Hz
- when the input signal level is 12 dB above the nominal value at a frequency of 1000 Hz
                                                             4.0 %
3.0 %
2.0 %
2.0 %
                                                                                                            3.0 %
2.0 %
2.0 %
                                                             -
-
-
-
                                                                                                    -
-
-
Protection from unweighted noise, max:
                                                                                                            
                                                             60 dB                                                        
                                                                                                            
                                                             -                                                        
                                                                                                    Increasing the output voltage level when the load is turned off,
vax:
- within the frequency range from 50 Hz to 6000 Hz inclusive
- over 6000 Hz
                                                                                                            vax:
- within the frequency range from 50 Hz to 6000 Hz inclusive
- over 6000 Hz
                                                             3.0 dB
4.0 dB
                                                                                                            4.0 dB
                                                             -
-
                                                                                                    -
Output voltage at load resistance two times lower than the nominal value, max
                                                                                                            
                                                             120 V                                                        
                                                                                                            
                                                             -                                                        
                                                                                                    An increase in the output signal level when a voltage is applied
to the input 4 times higher than the nominal, max
                                                                                                            to the input 4 times higher than the nominal, max
                                                             0.5 dB                                                        
                                                                                                            
                                                             -                                                        
                                                                                                    Amplifier impedance module at the input intended for connecting the line
- input 1
- input 2
                                                                                                            - input 1
- input 2
                                                             600 Ohm
1200 Ohm
                                                                                                            1200 Ohm
                                                             ±60 Ohm
±120 Ohm
                                                                                                    ±120 Ohm
Output voltage at complex load with phase angle ±45 degrees, not less than:
- at Kg 125 Hz, not more than
- at Kg 2000 Hz, not more than
                                                                                                            - at Kg 125 Hz, not more than
- at Kg 2000 Hz, not more than
                                                             168 V
3%
2%
                                                                                                            3%
2%
                                                             -
-
-
                                                                                                    -
-
Power consumed from AC network with rated voltage 220 V, 50 Hz, not more than:
- in nominal mode
- with an output voltage equal to 0.3 of the nominal
                                                                                                            - in nominal mode
- with an output voltage equal to 0.3 of the nominal
                                                             24600 W
3600 W
                                                                                                            3600 W
                                                             -
-
                                                                                                    -
Dimensions and Weight
- height
- width
- depth
- weight
                                                                                                            - height
- width
- depth
- weight
                                                             1850 mm
620 mm
630 mm
325 kg
                                                                                                            620 mm
630 mm
325 kg
                                                             -
-
-
-
                                                                                                    -
-
-
Download
                                                                            
                                                                     
                    