Yenisei D 5.0

Yenisei D 5.0

Description
Specifications
Description
  • The amplifier "YENISEY D5.0" is designed to amplify the signal of the nominal level 0.775V (0dB) coming from the source of the sound program to the level of 240V (50dB) at the nominal load
  • The amplifier is made in the form of a 19" rack, which houses a set of blocks providing a power of 5000 W
  • Amplifier output transformer balanced, protected by a fusible link
  • The amplifier is powered from a three-phase AC network with a voltage of 3x380V, 50Hz, with the obligatory connection of the neutral and ground wires.
  • The amplifier has a protection system:
    Thermal protection circuit implemented in the power amplifier unit
    Circuit for monitoring the health of fuses in the audio signal path
    Overload protection circuit in each PSU (power supply)
    It is provided to turn off the amplifier when any of the phases is lost

    Application:
  • Wired broadcasting networks
  • As part of warning systems for civil defense and emergencies
  • As part of systems used to conduct vibration tests


Specifications
Parameter name
Rated value
Limit
Rated output voltage
240 V
± 12 V
Rated input voltage
corresponding to the rated output
0,775 V
± 0,04 V
Rated output power when operating
on an active load 92.16 Ohm
5000 W
±500 W
Bandwidth transmitted frequencies
50-10000 Hz
-
Permissible deviations of the amplitude-frequency
characteristic (AFC), relative to the frequency
of 1000 Hz, max, at frequencies:
- 25 Hz
- from 25 Hz to 75 Hz inclusive
- over 75 Hz up to and including 100 Hz
- over 100 Hz up to and including 6600 Hz
- over 6600 Hz up to and including 10000 Hz
- 20000 Hz
-10,5 dB
-2,5 dB
-1 dB
±0,6 dB
1/-1,5 dB
-9 dB
±4,5 dB
±1,5 dB
±1,0 dB
-
-
±3,0 dB
Harmonic coefficient, max:
- at input voltage levels from minus 20 dB to the nominal value, at frequencies:
- up to 100 Hz
- from 100 Hz to 200 Hz inclusive
- over 200 Hz
- when the input signal level is 12 dB above the nominal value at a frequency of 1000 Hz
4.0 %
3.0 %
2.0 %
2.0 %
-
-
-
-
Protection from unweighted noise, max:
60 dB
-
Increasing the output voltage level when the load is turned off,
vax:
- within the frequency range from 50 Hz to 6000 Hz inclusive
- over 6000 Hz
3.0 dB
4.0 dB
-
-
Output voltage at load resistance two times lower than the nominal value, max
120 V
-
An increase in the output signal level when a voltage is applied
to the input 4 times higher than the nominal, max
0.5 dB
-
Amplifier impedance module at the input intended for connecting the line
- input 1
- input 2
600 Ohm
1200 Ohm
±60 Ohm
±120 Ohm
Output voltage at complex load with phase angle
±45 degrees, not less than:
- at Kg 125 Hz, not more than
- at Kg 2000 Hz, not more than
168 V
3%
2%
-
-
-
Power consumed from AC network with rated voltage 220 V, 50 Hz, not more than:
- in nominal mode
- with an output voltage equal to 0.3 of the nominal
8200 W
1200 W
-
-
Dimensions and Weight
- height
- width
- depth
- weight
1360 mm
620 mm
630 mm
175 kg

-
-
-
-